Medical Equipment Hospital Color LCD Multi-Parameter Portable Patient Monitor

Medical Equipment Hospital Color LCD Multi-Parameter Portable Patient Monitor
Product Introduction:

PM-7000D

Multi-parameter Patient Monitor

Social Share:
Send Inquiry
Description
Technical Parameters




Unique Features




● Original perfusion index (Pl) and show signal quality of blood oxygen infusion.

● Activated ETCO2 port, optional ETCO2 module plug and play on different patient monitors One key reset alarm preset values.

● Arrhythmia analysis, ST segment analysis and drug concentration and titration table calculation, ST base dot automatically adjustment.

● Defibrillation and resistance electrome design.




Parameter Specification




ECG

Meet the standards

ANSI/AAMI EC13:2002, IEC 60601-2-27:2011

Lead configuration

Standard three-guide or five-guide cable:

Three-guide: RA、LA、LL, Method of leads: I,II,III;
Five-guide: RA、LA、LL、RL、V,

Method of leads: I,II,III,aVR,aVL,aVF,V

Lead standard

AHA、IEC

display sensitivity

At least 1.25 mm/mV (×0.125), 2.5 mm/mV (×0.25), 5 mm/mV (×0.5), 10 mm/mV (×1), 20 mm/mV (×2) and automatic gain are supported, with an error of less than ±5%.
Add ±300 mV DC polarization voltage, sensitivity variation range ±5%

Wave scanning speed

At least three scanning speeds of 50mm /s, 25mm /s and 12.5mm /s can be provided with an error of no more than ±10%.


RESP

Measurement mode

Thoracic Electrical Bioimpedance

Measure the lead

Lead I and II are optional. Default is lead II

Bandwidth

0.2~2.5 Hz(-3dB)

Scanning speed

12.5 mm/s、25mm/s、50 mm/s

RR range

Adults:0 rpm~120 rpm

Children、newborn:0 rpm~150 rpm

RR resolution

1 rpm

Accuracy

8 RPM ~ 150 RPM: ±2 RPM or ± 2%, whichever is larger
Other scope is not defined.

Suffocation alarm delay

10 s、15 s、20 s、25 s、30 s、35 s、40 s


SpO2

Oxygen saturation measurement

Measurement range: 0% ~ 100%; Resolution: 1%

Accuracy

70% ~ 100%: error ≤±2%;
Within the range of 0% to 69%: not defined.

Replacement cycle

1 s

Perfusion index

0.05%~ 20%, precision undefined

Blood oxygen saturation alarm setting range

1) Alarm high limit: 2% ~ 100%;
2) Low alarm limit: 0% ~ 98%;
3) Alarm error: ±1%.


NIBP

Meet the standard

IEC 60601-2-30, IEC 60601-2-49,ANSI/AAMI SP10

Measurement mode

succussion

Operating mode

Manual/automatic/continuous measurement

Automatic measurement mode measurement interval time

1,2,3,4,5,10,15,30,60,90,120,180,240,480 minutes

Continuous mode measurement time

5 min


PR

Measurement range

30bpm~250bpm

Resolution

1bpm

Accuracy

±2bpm or 2%

Alarm limit

1)Adult

Alarm high limit: 17bpm~300bpm;

Alarm low limit: 15bpm~295bpm;
2) Pediatric

Alarm high limit: 17bpm~350bpm;

Alarm low limit: 15bpm~345bpm;

3) Neonate

Alarm high limit: 17bpm~350bpm;

Alarm low limit: 15bpm~345bpm;




Q&A




Q:How can we get a quote?

A:Contact us with specification: such as material, design, size, shape, color, quantity, surface finishing, etc.


Q:Do you have the certification of the products?

A:Yes,we have some certifications of the product, such as ISO、FSC and CE certifications.


 

Hot Tags: portable multi-parameter patient monitor, China, manufacturers, customized, cheap, discount, high quality, low price, digital 12 channel EKG machine, 21 Inch LCD Monitor Radiology Ultrasound, High Resolution Color Doppler Cardiovascular Ultrasound, Central Monitoring Solution for patient monitor, Real time Data Store and analysis Ambulatory Blood Pressure Monitor, Entry Level B W General Imaging Ultrasound

Send Inquiry
Send Inquiry