Unique Features |
● Original perfusion index (Pl) and show signal quality of blood oxygen infusion. ● Activated ETCO2 port, optional ETCO2 module plug and play on different patient monitors One key reset alarm preset values. ● Arrhythmia analysis, ST segment analysis and drug concentration and titration table calculation, ST base dot automatically adjustment. ● Defibrillation and resistance electrome design. |
Parameter Specification |
ECG | |
Meet the standards | ANSI/AAMI EC13:2002, IEC 60601-2-27:2011 |
Lead configuration | Standard three-guide or five-guide cable: Three-guide: RA、LA、LL, Method of leads: I,II,III; Method of leads: I,II,III,aVR,aVL,aVF,V |
Lead standard | AHA、IEC |
display sensitivity | At least 1.25 mm/mV (×0.125), 2.5 mm/mV (×0.25), 5 mm/mV (×0.5), 10 mm/mV (×1), 20 mm/mV (×2) and automatic gain are supported, with an error of less than ±5%. |
Wave scanning speed | At least three scanning speeds of 50mm /s, 25mm /s and 12.5mm /s can be provided with an error of no more than ±10%. |
RESP | |
Measurement mode | Thoracic Electrical Bioimpedance |
Measure the lead | Lead I and II are optional. Default is lead II |
Bandwidth | 0.2~2.5 Hz(-3dB) |
Scanning speed | 12.5 mm/s、25mm/s、50 mm/s |
RR range | Adults:0 rpm~120 rpm Children、newborn:0 rpm~150 rpm |
RR resolution | 1 rpm |
Accuracy | 8 RPM ~ 150 RPM: ±2 RPM or ± 2%, whichever is larger |
Suffocation alarm delay | 10 s、15 s、20 s、25 s、30 s、35 s、40 s |
SpO2 | |
Oxygen saturation measurement | Measurement range: 0% ~ 100%; Resolution: 1% |
Accuracy | 70% ~ 100%: error ≤±2%; |
Replacement cycle | 1 s |
Perfusion index | 0.05%~ 20%, precision undefined |
Blood oxygen saturation alarm setting range | 1) Alarm high limit: 2% ~ 100%; |
NIBP | |
Meet the standard | IEC 60601-2-30, IEC 60601-2-49,ANSI/AAMI SP10 |
Measurement mode | succussion |
Operating mode | Manual/automatic/continuous measurement |
Automatic measurement mode measurement interval time | 1,2,3,4,5,10,15,30,60,90,120,180,240,480 minutes |
Continuous mode measurement time | 5 min |
PR | |
Measurement range | 30bpm~250bpm |
Resolution | 1bpm |
Accuracy | ±2bpm or 2% |
Alarm limit | 1)Adult Alarm high limit: 17bpm~300bpm; Alarm low limit: 15bpm~295bpm; Alarm high limit: 17bpm~350bpm; Alarm low limit: 15bpm~345bpm; 3) Neonate Alarm high limit: 17bpm~350bpm; Alarm low limit: 15bpm~345bpm; |
Q&A |
Q:How can we get a quote? A:Contact us with specification: such as material, design, size, shape, color, quantity, surface finishing, etc. Q:Do you have the certification of the products? A:Yes,we have some certifications of the product, such as ISO、FSC and CE certifications. |
Hot Tags: portable multi-parameter patient monitor, China, manufacturers, customized, cheap, discount, high quality, low price, digital 12 channel EKG machine, 21 Inch LCD Monitor Radiology Ultrasound, High Resolution Color Doppler Cardiovascular Ultrasound, Central Monitoring Solution for patient monitor, Real time Data Store and analysis Ambulatory Blood Pressure Monitor, Entry Level B W General Imaging Ultrasound